summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorFelix Fietkau <nbd@openwrt.org>2010-01-08 18:06:26 +0100
committerJohn W. Linville <linville@tuxdriver.com>2010-01-12 14:02:06 -0500
commitd524215f6cad245249df8def19125ae6fd0bcc9b (patch)
tree4ddbf4b50005a41a8ac69e2d156a78edd47f457d
parent199afd9d89b18e8b530734ed73788518e19bed9b (diff)
mac80211: use nullfunc frames for 4-addr sta detection
To detect incoming 4-addr stations, hostapd needs to receive a 4-addr data frame from the remote station, so that it can create the AP VLAN for it. With this patch, the mlme code emits a 4-addr nullfunc frame immediately after assoc. On the AP side it also drops 4-addr nullfunc frames to the cooked monitor mode interface, if the interface hasn't been fully set up to receive 4-addr data frames yet. Signed-off-by: Felix Fietkau <nbd@openwrt.org> Signed-off-by: John W. Linville <linville@tuxdriver.com>
-rw-r--r--net/mac80211/mlme.c39
-rw-r--r--net/mac80211/rx.c12
2 files changed, 51 insertions, 0 deletions
diff --git a/net/mac80211/mlme.c b/net/mac80211/mlme.c
index 5484cf930a8..0336dbb45ac 100644
--- a/net/mac80211/mlme.c
+++ b/net/mac80211/mlme.c
@@ -282,6 +282,38 @@ void ieee80211_send_nullfunc(struct ieee80211_local *local,
ieee80211_tx_skb(sdata, skb);
}
+static void ieee80211_send_4addr_nullfunc(struct ieee80211_local *local,
+ struct ieee80211_sub_if_data *sdata)
+{
+ struct sk_buff *skb;
+ struct ieee80211_hdr *nullfunc;
+ __le16 fc;
+
+ if (WARN_ON(sdata->vif.type != NL80211_IFTYPE_STATION))
+ return;
+
+ skb = dev_alloc_skb(local->hw.extra_tx_headroom + 30);
+ if (!skb) {
+ printk(KERN_DEBUG "%s: failed to allocate buffer for 4addr "
+ "nullfunc frame\n", sdata->name);
+ return;
+ }
+ skb_reserve(skb, local->hw.extra_tx_headroom);
+
+ nullfunc = (struct ieee80211_hdr *) skb_put(skb, 30);
+ memset(nullfunc, 0, 30);
+ fc = cpu_to_le16(IEEE80211_FTYPE_DATA | IEEE80211_STYPE_NULLFUNC |
+ IEEE80211_FCTL_FROMDS | IEEE80211_FCTL_TODS);
+ nullfunc->frame_control = fc;
+ memcpy(nullfunc->addr1, sdata->u.mgd.bssid, ETH_ALEN);
+ memcpy(nullfunc->addr2, sdata->vif.addr, ETH_ALEN);
+ memcpy(nullfunc->addr3, sdata->u.mgd.bssid, ETH_ALEN);
+ memcpy(nullfunc->addr4, sdata->vif.addr, ETH_ALEN);
+
+ IEEE80211_SKB_CB(skb)->flags |= IEEE80211_TX_INTFL_DONT_ENCRYPT;
+ ieee80211_tx_skb(sdata, skb);
+}
+
/* spectrum management related things */
static void ieee80211_chswitch_work(struct work_struct *work)
{
@@ -1090,6 +1122,13 @@ static bool ieee80211_assoc_success(struct ieee80211_work *wk,
ieee80211_set_associated(sdata, cbss, changed);
/*
+ * If we're using 4-addr mode, let the AP know that we're
+ * doing so, so that it can create the STA VLAN on its side
+ */
+ if (ifmgd->use_4addr)
+ ieee80211_send_4addr_nullfunc(local, sdata);
+
+ /*
* Start timer to probe the connection to the AP now.
* Also start the timer that will detect beacon loss.
*/
diff --git a/net/mac80211/rx.c b/net/mac80211/rx.c
index e12f39a9646..efa6d3689c5 100644
--- a/net/mac80211/rx.c
+++ b/net/mac80211/rx.c
@@ -1111,6 +1111,18 @@ ieee80211_rx_h_sta_process(struct ieee80211_rx_data *rx)
if (ieee80211_is_nullfunc(hdr->frame_control) ||
ieee80211_is_qos_nullfunc(hdr->frame_control)) {
I802_DEBUG_INC(rx->local->rx_handlers_drop_nullfunc);
+
+ /*
+ * If we receive a 4-addr nullfunc frame from a STA
+ * that was not moved to a 4-addr STA vlan yet, drop
+ * the frame to the monitor interface, to make sure
+ * that hostapd sees it
+ */
+ if (ieee80211_has_a4(hdr->frame_control) &&
+ (rx->sdata->vif.type == NL80211_IFTYPE_AP ||
+ (rx->sdata->vif.type == NL80211_IFTYPE_AP_VLAN &&
+ !rx->sdata->u.vlan.sta)))
+ return RX_DROP_MONITOR;
/*
* Update counter and free packet here to avoid
* counting this as a dropped packed.