diff options
author | xmarvla <vlatko.markovic@seavus.com> | 2011-06-15 14:03:08 +0200 |
---|---|---|
committer | Viktor Mladenovski <viktor.mladenovski@seavus.com> | 2011-08-17 22:06:38 +0200 |
commit | c9d1f9613e3ac18d5dd3b9432646e289bb88cec9 (patch) | |
tree | 086b18dc26d75f052b840d818877efb79f5791ca /lcmodule/source/cnh1606344_ldr_communication_module/config/error_codes.xml | |
parent | 12da7d3751c8b7bd088587c8323123019680efff (diff) |
Add support for M730 Platform
Added new command: System_StartCommRelay (For M730 platform).
New state machine in Protrom Network Transmitter Handler.
Small changes in Z protocol due to implementation of
Communication Relay in Hassium Loaders.
Add implementation for CriticalSection synchronization mechanism.
ST-Ericsson ID: 325251
ST-Ericsson FOSS-OUT ID: STETL-FOSS-OUT-10204
Depends-On: I0d34a2c4504a2b52ff5ab5efd2da36d8d1fa9816
Change-Id: I0d34a2c4504a2b52ff5ab5efd2da36d8d1fa9816
Reviewed-on: http://gerrit.lud.stericsson.com/gerrit/20944
Reviewed-by: QATOOLS
Reviewed-by: Vlatko PISTOLOV <vlatko.pistolov@seavus.com>
Tested-by: Vlatko PISTOLOV <vlatko.pistolov@seavus.com>
Diffstat (limited to 'lcmodule/source/cnh1606344_ldr_communication_module/config/error_codes.xml')
-rw-r--r-- | lcmodule/source/cnh1606344_ldr_communication_module/config/error_codes.xml | 8 |
1 files changed, 8 insertions, 0 deletions
diff --git a/lcmodule/source/cnh1606344_ldr_communication_module/config/error_codes.xml b/lcmodule/source/cnh1606344_ldr_communication_module/config/error_codes.xml index 549b369..138c902 100644 --- a/lcmodule/source/cnh1606344_ldr_communication_module/config/error_codes.xml +++ b/lcmodule/source/cnh1606344_ldr_communication_module/config/error_codes.xml @@ -563,6 +563,14 @@ <value number="2755" name="E_HSI_BSC_ERROR_TRANSMIT" fatal="true" short="Transmit buffer is not provided.">Reset loader.Report if problem still exist.</value> <!-- + * Communication Relay Error Codes + * Communication Relay Fatal 2800-2849 + * Communication Relay Non-Fatal 2850-2899 + --> + <value number="2850" name="E_CR_INVALID_STATE" fatal="false" short="Invalid state for commnication relay detected.">Wrong value passed as state for the communication relay and hence it can't be used. Try setting some of predifined communication relay states.</value> + <value number="2851" name="E_CR_NOT_RUNNING" fatal="false" short="Communication Relay is not running.">Communication relay is set in error state or it is not configured properly. Check the relay state. If error occured restart the loader, otherwise try reconfiguring the relay.</value> + + <!-- * Security Library Fatal 4000-4050 * Security Library non-fatal 4051-4250 --> |