Add support for M730 Platform
Added new command: System_StartCommRelay (For M730 platform). New state machine in Protrom Network Transmitter Handler. Small changes in Z protocol due to implementation of Communication Relay in Hassium Loaders. Add implementation for CriticalSection synchronization mechanism. ST-Ericsson ID: 325251 ST-Ericsson FOSS-OUT ID: STETL-FOSS-OUT-10204 Depends-On: I0d34a2c4504a2b52ff5ab5efd2da36d8d1fa9816 Change-Id: I0d34a2c4504a2b52ff5ab5efd2da36d8d1fa9816 Reviewed-on: http://gerrit.lud.stericsson.com/gerrit/20944 Reviewed-by: QATOOLS Reviewed-by: Vlatko PISTOLOV <vlatko.pistolov@seavus.com> Tested-by: Vlatko PISTOLOV <vlatko.pistolov@seavus.com>
Diffstat (limited to 'lcmodule/source/cnh1606344_ldr_communication_module/config/error_codes.xml')
-rw-r--r--lcmodule/source/cnh1606344_ldr_communication_module/config/error_codes.xml8
1 files changed, 8 insertions, 0 deletions
diff --git a/lcmodule/source/cnh1606344_ldr_communication_module/config/error_codes.xml b/lcmodule/source/cnh1606344_ldr_communication_module/config/error_codes.xml
index 549b369..138c902 100644
--- a/lcmodule/source/cnh1606344_ldr_communication_module/config/error_codes.xml
+++ b/lcmodule/source/cnh1606344_ldr_communication_module/config/error_codes.xml
@@ -563,6 +563,14 @@
<value number="2755" name="E_HSI_BSC_ERROR_TRANSMIT" fatal="true" short="Transmit buffer is not provided.">Reset loader.Report if problem still exist.</value>
<!--
+ * Communication Relay Error Codes
+ * Communication Relay Fatal 2800-2849
+ * Communication Relay Non-Fatal 2850-2899
+ -->
+ <value number="2850" name="E_CR_INVALID_STATE" fatal="false" short="Invalid state for commnication relay detected.">Wrong value passed as state for the communication relay and hence it can't be used. Try setting some of predifined communication relay states.</value>
+ <value number="2851" name="E_CR_NOT_RUNNING" fatal="false" short="Communication Relay is not running.">Communication relay is set in error state or it is not configured properly. Check the relay state. If error occured restart the loader, otherwise try reconfiguring the relay.</value>
+
+ <!--