From 81472d893fa565c9d300928a40e504a689bde131 Mon Sep 17 00:00:00 2001 From: Ladislav Michl Date: Mon, 30 Mar 2009 18:58:41 +0200 Subject: OMAP: rename timer divisor Divisor field is called PTV not PVT. Signed-off-by: Ladislav Michl Signed-off-by: Jean-Christophe PLAGNIOL-VILLARD --- include/configs/omap3_beagle.h | 6 ++---- 1 file changed, 2 insertions(+), 4 deletions(-) (limited to 'include/configs/omap3_beagle.h') diff --git a/include/configs/omap3_beagle.h b/include/configs/omap3_beagle.h index ad00b4c29..7db1eb754 100644 --- a/include/configs/omap3_beagle.h +++ b/include/configs/omap3_beagle.h @@ -226,11 +226,9 @@ * 2430 has 12 GP timers, they can be driven by the SysClk (12/13/19.2) or by * 32KHz clk, or from external sig. This rate is divided by a local divisor. */ -#define V_PVT 7 - #define CONFIG_SYS_TIMERBASE (OMAP34XX_GPT2) -#define CONFIG_SYS_PVT V_PVT /* 2^(pvt+1) */ -#define CONFIG_SYS_HZ ((V_SCLK) / (2 << CONFIG_SYS_PVT)) +#define CONFIG_SYS_PTV 7 /* 2^(PTV+1) */ +#define CONFIG_SYS_HZ ((V_SCLK) / (2 << CONFIG_SYS_PTV)) /*----------------------------------------------------------------------- * Stack sizes -- cgit v1.2.3