summaryrefslogtreecommitdiff
path: root/drivers
diff options
context:
space:
mode:
authorChaitanya Kulkarni <chaitanya.kulkarni@wdc.com>2021-01-13 17:33:52 -0800
committerChristoph Hellwig <hch@lst.de>2021-02-02 10:26:11 +0100
commit624e67fdf9a657fe437d84dd9f28b35e594183dd (patch)
tree25d3759e436bb9d80a3f85ec48b4ddcf1f98600e /drivers
parentfc97e942d90c2103755f2fcd9a068a4ee7dfc1bf (diff)
nvmet: remove extra variable in smart log nsid
We remove the extra local variable struct nvmet_ns in nvmet_get_smart_log_nsid() since req already has ns member that can be reused, this also eliminates the explicit call to nvmet_put_namespace() which is already present in the request completion path. Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com> Reviewed-by: Sagi Grimberg <sagi@grimberg.me> Signed-off-by: Christoph Hellwig <hch@lst.de>
Diffstat (limited to 'drivers')
-rw-r--r--drivers/nvme/target/admin-cmd.c20
1 files changed, 9 insertions, 11 deletions
diff --git a/drivers/nvme/target/admin-cmd.c b/drivers/nvme/target/admin-cmd.c
index dc1ea468b182..de804d9762dd 100644
--- a/drivers/nvme/target/admin-cmd.c
+++ b/drivers/nvme/target/admin-cmd.c
@@ -74,11 +74,11 @@ static void nvmet_execute_get_log_page_error(struct nvmet_req *req)
static u16 nvmet_get_smart_log_nsid(struct nvmet_req *req,
struct nvme_smart_log *slog)
{
- struct nvmet_ns *ns;
u64 host_reads, host_writes, data_units_read, data_units_written;
- ns = nvmet_find_namespace(req->sq->ctrl, req->cmd->get_log_page.nsid);
- if (!ns) {
+ req->ns = nvmet_find_namespace(req->sq->ctrl,
+ req->cmd->get_log_page.nsid);
+ if (!req->ns) {
pr_err("Could not find namespace id : %d\n",
le32_to_cpu(req->cmd->get_log_page.nsid));
req->error_loc = offsetof(struct nvme_rw_command, nsid);
@@ -86,22 +86,20 @@ static u16 nvmet_get_smart_log_nsid(struct nvmet_req *req,
}
/* we don't have the right data for file backed ns */
- if (!ns->bdev)
- goto out;
+ if (!req->ns->bdev)
+ return NVME_SC_SUCCESS;
- host_reads = part_stat_read(ns->bdev, ios[READ]);
+ host_reads = part_stat_read(req->ns->bdev, ios[READ]);
data_units_read =
- DIV_ROUND_UP(part_stat_read(ns->bdev, sectors[READ]), 1000);
- host_writes = part_stat_read(ns->bdev, ios[WRITE]);
+ DIV_ROUND_UP(part_stat_read(req->ns->bdev, sectors[READ]), 1000);
+ host_writes = part_stat_read(req->ns->bdev, ios[WRITE]);
data_units_written =
- DIV_ROUND_UP(part_stat_read(ns->bdev, sectors[WRITE]), 1000);
+ DIV_ROUND_UP(part_stat_read(req->ns->bdev, sectors[WRITE]), 1000);
put_unaligned_le64(host_reads, &slog->host_reads[0]);
put_unaligned_le64(data_units_read, &slog->data_units_read[0]);
put_unaligned_le64(host_writes, &slog->host_writes[0]);
put_unaligned_le64(data_units_written, &slog->data_units_written[0]);
-out:
- nvmet_put_namespace(ns);
return NVME_SC_SUCCESS;
}