Maxim MAX31856 thermocouple support https://datasheets.maximintegrated.com/en/ds/MAX31856.pdf Optional property: - thermocouple-type: Type of thermocouple (THERMOCOUPLE_TYPE_K if omitted). Supported types are B, E, J, K, N, R, S, T. Required properties: - compatible: must be "maxim,max31856" - reg: SPI chip select number for the device - spi-max-frequency: As per datasheet max. supported freq is 5000000 - spi-cpha: must be defined for max31856 to enable SPI mode 1 Refer to spi/spi-bus.txt for generic SPI slave bindings. Example: temp-sensor@0 { compatible = "maxim,max31856"; reg = <0>; spi-max-frequency = <5000000>; spi-cpha; thermocouple-type = ; };