summaryrefslogtreecommitdiff
path: root/Documentation/hwmon
diff options
context:
space:
mode:
authorDonggeun Kim <dg77.kim@samsung.com>2011-09-07 18:49:08 +0900
committerGuenter Roeck <guenter.roeck@ericsson.com>2011-10-24 11:09:35 -0700
commit9d97e5c81e15afaef65d00f077f863c94f750839 (patch)
tree01df55fd37f2432ec03c29bf55cc97dfdb6f1b60 /Documentation/hwmon
parent5cf231a346fb80d7945aa46e90186a068a3a001b (diff)
hwmon: Add driver for EXYNOS4 TMU
This patch allows to read temperature from TMU(Thermal Management Unit) of SAMSUNG EXYNOS4 series of SoC. Signed-off-by: Donggeun Kim <dg77.kim@samsung.com> Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/exynos4_tmu81
1 files changed, 81 insertions, 0 deletions
diff --git a/Documentation/hwmon/exynos4_tmu b/Documentation/hwmon/exynos4_tmu
new file mode 100644
index 00000000000..c3c6b41db60
--- /dev/null
+++ b/Documentation/hwmon/exynos4_tmu
@@ -0,0 +1,81 @@
+Kernel driver exynos4_tmu
+=================
+
+Supported chips:
+* ARM SAMSUNG EXYNOS4 series of SoC
+ Prefix: 'exynos4-tmu'
+ Datasheet: Not publicly available
+
+Authors: Donggeun Kim <dg77.kim@samsung.com>
+
+Description
+-----------
+
+This driver allows to read temperature inside SAMSUNG EXYNOS4 series of SoC.
+
+The chip only exposes the measured 8-bit temperature code value
+through a register.
+Temperature can be taken from the temperature code.
+There are three equations converting from temperature to temperature code.
+
+The three equations are:
+ 1. Two point trimming
+ Tc = (T - 25) * (TI2 - TI1) / (85 - 25) + TI1
+
+ 2. One point trimming
+ Tc = T + TI1 - 25
+
+ 3. No trimming
+ Tc = T + 50
+
+ Tc: Temperature code, T: Temperature,
+ TI1: Trimming info for 25 degree Celsius (stored at TRIMINFO register)
+ Temperature code measured at 25 degree Celsius which is unchanged
+ TI2: Trimming info for 85 degree Celsius (stored at TRIMINFO register)
+ Temperature code measured at 85 degree Celsius which is unchanged
+
+TMU(Thermal Management Unit) in EXYNOS4 generates interrupt
+when temperature exceeds pre-defined levels.
+The maximum number of configurable threshold is four.
+The threshold levels are defined as follows:
+ Level_0: current temperature > trigger_level_0 + threshold
+ Level_1: current temperature > trigger_level_1 + threshold
+ Level_2: current temperature > trigger_level_2 + threshold
+ Level_3: current temperature > trigger_level_3 + threshold
+
+ The threshold and each trigger_level are set
+ through the corresponding registers.
+
+When an interrupt occurs, this driver notify user space of
+one of four threshold levels for the interrupt
+through kobject_uevent_env and sysfs_notify functions.
+Although an interrupt condition for level_0 can be set,
+it is not notified to user space through sysfs_notify function.
+
+Sysfs Interface
+---------------
+name name of the temperature sensor
+ RO
+
+temp1_input temperature
+ RO
+
+temp1_max temperature for level_1 interrupt
+ RO
+
+temp1_crit temperature for level_2 interrupt
+ RO
+
+temp1_emergency temperature for level_3 interrupt
+ RO
+
+temp1_max_alarm alarm for level_1 interrupt
+ RO
+
+temp1_crit_alarm
+ alarm for level_2 interrupt
+ RO
+
+temp1_emergency_alarm
+ alarm for level_3 interrupt
+ RO