diff options
author | Julius Werner <jwerner@chromium.org> | 2014-03-04 10:52:39 -0800 |
---|---|---|
committer | Greg Kroah-Hartman <gregkh@linuxfoundation.org> | 2014-03-07 11:46:51 -0800 |
commit | e0429362ab15c46ea4d64c3f8c9e0933e48a143a (patch) | |
tree | 563b7b4f7b76863dece546668b9b3319ff9abe51 | |
parent | 0414855fdc4a40da05221fc6062cccbc0c30f169 (diff) |
usb: Add device quirk for Logitech HD Pro Webcams C920 and C930e
We've encountered a rare issue when enumerating two Logitech webcams
after a reboot that doesn't power cycle the USB ports. They are spewing
random data (possibly some leftover UVC buffers) on the second
(full-sized) Get Configuration request of the enumeration phase. Since
the data is random this can potentially cause all kinds of odd behavior,
and since it occasionally happens multiple times (after the kernel
issues another reset due to the garbled configuration descriptor), it is
not always recoverable. Set the USB_DELAY_INIT quirk that seems to work
around the issue.
Signed-off-by: Julius Werner <jwerner@chromium.org>
Cc: stable <stable@vger.kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-rw-r--r-- | drivers/usb/core/quirks.c | 4 |
1 files changed, 4 insertions, 0 deletions
diff --git a/drivers/usb/core/quirks.c b/drivers/usb/core/quirks.c index 8f37063c0a49..739ee8e8bdfd 100644 --- a/drivers/usb/core/quirks.c +++ b/drivers/usb/core/quirks.c @@ -47,6 +47,10 @@ static const struct usb_device_id usb_quirk_list[] = { /* Microsoft LifeCam-VX700 v2.0 */ { USB_DEVICE(0x045e, 0x0770), .driver_info = USB_QUIRK_RESET_RESUME }, + /* Logitech HD Pro Webcams C920 and C930e */ + { USB_DEVICE(0x046d, 0x082d), .driver_info = USB_QUIRK_DELAY_INIT }, + { USB_DEVICE(0x046d, 0x0843), .driver_info = USB_QUIRK_DELAY_INIT }, + /* Logitech Quickcam Fusion */ { USB_DEVICE(0x046d, 0x08c1), .driver_info = USB_QUIRK_RESET_RESUME }, |