summaryrefslogtreecommitdiff
path: root/tools/perf/scripts/python/export-to-postgresql.py
diff options
context:
space:
mode:
authorBoris Brezillon <boris.brezillon@free-electrons.com>2016-06-14 11:13:20 +0200
committerThierry Reding <thierry.reding@gmail.com>2016-07-11 08:44:29 +0200
commitd9070fdbe40a04b61262bac0f7ff0c7c29a68015 (patch)
tree06eb17c64d51968825b97a9ed43e7aa2a159e1d9 /tools/perf/scripts/python/export-to-postgresql.py
parent87248991a1de28e73dc30057e82d831bc11cdd44 (diff)
regulator: pwm: Retrieve correct voltage
The continuous PWM voltage regulator is caching the voltage value in the ->volt_uV field. While most of the time this value should reflect the real voltage, sometime it can be sightly different if the PWM device rounded the set_duty_cycle request. Moreover, this value is not valid until someone has modified the regulator output. Remove the ->volt_uV field and always rely on the PWM state to calculate the regulator output. Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com> Reviewed-by: Brian Norris <briannorris@chromium.org> Tested-by: Brian Norris <briannorris@chromium.org> Tested-by: Heiko Stuebner <heiko@sntech.de> Acked-by: Mark Brown <broonie@kernel.org> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
Diffstat (limited to 'tools/perf/scripts/python/export-to-postgresql.py')
0 files changed, 0 insertions, 0 deletions